Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: Data of one-year prospective clinical study

8Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

Objective. To evaluate and compare the impact of two sharp-edge optic foldable intraocular lenses (IOLs) of similar design made from different material (hydrophilic acrylic or hydrophobic acrylic) on visual function, anterior and posterior capsule opacification at one-year follow-up after cataract phacoemulsification. Material and Methods. Seventy-two eyes of 72 patients scheduled for cataract surgery were included in a prospective clinical study. Two foldable sharp-edge optic posterior chamber acrylic IOLs of similar design were used. Thirty-nine eyes of 39 patients received a single-piece hydrophilic acrylic (PC 511, Ophtec) IOL and 33 eyes of 33 patients - single-piece hydrophobic acrylic (AcrySof, SA60AT, Alcon) IOL. Visual acuity, anterior capsule opacification (ACO), capsulorrhexis/ optic overlapping, and posterior capsule opacificati6n (PCO) were evaluated. The intensity of ACO was assessed subjectively. PCO values in the entire IOL optic area and in the central 3-mm optic zone were assessed using a photographic image analysis system (EPCO 2000). The patients were examined at one year postoperatively. Results. There were no significant differences in best-corrected visual acuity and capsulorrhexis/optic overlapping between IOL types at 1-year follow-up after surgery. In the single-piece hydrophilic acrylic IOL group, the grade of ACO density was significantly higher in capsulorrhexis rim area (1.56±0.71 and 1.00±0.75) and in the capsule/optic area (1.62±0.67 and 1.00±0.75) (PO.05). PCO values of the entire IOL optic area (0.12±0.13 and 0.024±0.02) as well as in the central 3-mm optic zone (0.06±0.11 and 0.001±0.003) was significantly higher in the single-piece hydrophilic acrylic IOL group one year postoperatively (P<0.05). In 33.3% of cases of the single-piece hydrophilic acrylic IOL group, contraction of haptics to IOL optics was present one year postoperatively, which was not present in any case of the single-piece hydrophobic acrylic IOL group. Conclusions. One-year follow-up after cataract surgery has shown a significant difference in ACO and PCO development comparing single-piece hydrophilic acrylic and single-piece hydrophobic acrylic intraocular lenses. The effect of hydrophobic acrylic foldable lenses on preventing anterior and posterior capsule opacification is mainly a result of the acrylic hydrophobic biomaterial.

Cite

CITATION STYLE

APA

Žemaitiene, R., Špečkauskas, M., Glebauskiene, B., & Jašinskas, V. (2008). Comparison of postoperative results after implantation of hydrophilic acrylic or hydrophobic acrylic intraocular lens: Data of one-year prospective clinical study. Medicina, 44(12), 936–943. https://doi.org/10.3390/medicina44120117

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free