Low Volume Vertebral Augmentation with Cortoss® Cement for Treatment of High Degree Vertebral Compression Fractures and Vertebra Plana

  • Jacobson R
  • Granville M
  • Hatgis J
  • et al.
N/ACitations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

This is a retrospective analysis of a consecutive series of patients undergoing vertebroplasty and vertebral augmentation in an outpatient setting for high degree osteoporotic vertebral fractures or vertebra plana using consistently low volumes (less than 3 cc) of Cortoss® cement, rather than polymethylmethacrylate (PMMA). The results in these patients demonstrate that it is both technically feasible to do vertebroplasty on these patients and using a low volume hydrophilic silica-based cement is effective in providing diffuse vertebral body fill with minimal complications. There was no increased risk of complications, such as cement leakage, displacement of bone fragments, or progression of the angulation. Specifically, with over a 24-month follow-up, the preoperative collapse or angulation did not worsen and none of the patients developed adjacent level fractures or required further surgery at the involved vertebral level.

Cite

CITATION STYLE

APA

Jacobson, R. E., Granville, M., Hatgis, J., & Berti, A. (2017). Low Volume Vertebral Augmentation with Cortoss® Cement for Treatment of High Degree Vertebral Compression Fractures and Vertebra Plana. Cureus. https://doi.org/10.7759/cureus.1058