Leadless pacemakers provide a potential alternative to conventional transvenous pacemakers for patients undergoing high-risk transcatheter valve replacement procedures. This is a description of a successful leadless pacemaker implantation in a 51-year-old woman who developed profound bradycardia following a transcatheter aortic valve replacement and mitral valve-in-valve procedure.

Cite

CITATION STYLE

APA

Gül, E. E., Haseeb, Y. B., Haseeb, S., Abuelatta, R., & Al Amoudi, O. (2020). Successful leadless pacemaker implantation in a patient with profound bradycardia following transcatheter aortic valve replacement and mitral valve-in-valve procedure. Turk Kardiyoloji Dernegi Arsivi, 48(4), 443–446. https://doi.org/10.5543/tkda.2020.46635