Preparation and full characterization of a micro-immunoaffinity monolithic column and its in-line coupling with capillary zone electrophoresis with Ochratoxin A as model solute

24Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A micro-immunoaffinity monolithic column (μIAC) was developed and in-line coupled with capillary zone electrophoresis in a fully automated way with Ochratoxin A as test solute. The in-line micro-immunoaffinity columns based on monolithic methacrylate polymers (EDMA-GMA) were prepared in situ at the inlet end of a PTFE coated fused silica capillary by UV initiated polymerization and subsequently grafted with antibodies. These μIACs were thoroughly characterized. The synthesis of the polymeric support was first demonstrated to be reproducible in terms of permeability, surface properties and efficiency. The antibodies immobilization was then studied by a new original hydrodynamic method (ADECA) allowing the in situ quantitative determination (at a miniaturized scale) of the total amount of immobilized antibodies. The combination of this measurement with the binding capacity of the μIAC allowed, for the first time, the in situ determination of immobilized antibody activity. A total of 260±15ng (1.6±0.1pmol) of IgG antibodies/cm in 75μm i.d. monolithic column (i.e. 18μgmg -1) was obtained with (anti-Ochratoxin A/Ochratoxin A) as antibody/antigen model. 40% of the immobilized antibodies remain active corresponding to a binding capacity of 1.2±0.2pmol antigen/cm (i.e. 600pg/cm of our test solute OTA), a very high capacity when dealing with trace analysis and with regard to the detection limits (30pg and 0.5pg with UV and LIF detection, respectively). The recovery yields were quantitative with negligible non-specific adsorption and allow analysis of diluted samples (1ngmL -1) for a percolated volume of 10μL. It was also demonstrated that despite the progressive denaturation of antibodies consecutive to the elution step, the binding capacity of the μIAC remained high enough to implement at least 15 consecutive analyses with the same column and in a fully automated way. © 2011 Elsevier B.V.

Cite

CITATION STYLE

APA

Chamieh, J., Faye, C., Dugas, V., Moreau, T., Vandenabeele-Trambouze, O., & Demesmay, C. (2012). Preparation and full characterization of a micro-immunoaffinity monolithic column and its in-line coupling with capillary zone electrophoresis with Ochratoxin A as model solute. Journal of Chromatography A, 1232, 93–100. https://doi.org/10.1016/j.chroma.2011.10.061

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free