Abstract
Different Advanced Oxidation Processes (Photo Fenton process, Fenton process and H 2 O 2 /UV) were studied in order to reduce COD from oily compounds aqueous solution using batch system. To get the optimum condition, different variables were studied for each of these processes; such as pH, time, concentration of H 2 O 2, concentration of oil, concentration of FeSO 4 ·7H 2 O and temperature as parameters. It was found that the optimal pH value for the three processes was 3 and the optimal temperature was 30 o C for Photo-Fenton and UV/H 2 O 2 system and 20 o C for Fenton process. Photo-Fenton process gave a maximum COD reduction of 80.59 % (COD from 2684 to 521 mg/l), Fenton gave 53.22 % (COD from 2587-1130) and the combination of UV/H 2 O 2 gave a COD reduction of 22.69 % (COD from 2450 to 1894). The percentage of removal found was after the total reaction time (180 min.). The optimum chemical reagents for Photo-Fenton, Fenton and UV/H 2 O 2 were as the following H 2 O 2 = 800 mg/l, 1500 mg/l and 2000 mg/l, Fe 2 SO 4 ·7H 2 O = 60 mg/l, 100 mg/l.
Cite
CITATION STYLE
Tahir, A. H. F., Kariem, N. O., & Ibrahim, S. A. (2016). COD Removal of Edible Oil Content in Wastewater by Advanced Oxidation Process. Environment and Natural Resources Research, 6(2), 57. https://doi.org/10.5539/enrr.v6n2p57
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.