The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: A prospective, diagnostic pilot study

53Citations
Citations of this article
75Readers
Mendeley users who have this article in their library.

Abstract

Objective: To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO2) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. Design: Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Setting: Postanaesthetic care unit in a tertiary hospital in Spain. Participants: Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. Intervention: The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO2 was ≤96% and negative when SpO2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. Main outcome measures: The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. Results: The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). Conclusion: The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis.

Cite

CITATION STYLE

APA

Ferrando, C., Romero, C., Tusman, G., Suarez-Sipmann, F., Canet, J., Dosdá, R., … Belda, F. J. (2017). The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: A prospective, diagnostic pilot study. BMJ Open, 7(5). https://doi.org/10.1136/bmjopen-2016-015560

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free