Spectroscopic measurement of cartilage thickness in arthroscopy: Ex vivo validation in human knee condyles

11Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To evaluate the accuracy of articular cartilage thickness measurement when implementing a new technology based on spectroscopic measurement into an arthroscopic camera. Methods: Cartilage thickness was studied by ex vivo arthroscopy at a number of sites (N = 113) in human knee joint osteoarthritic femoral condyles and tibial plateaus, removed from 7 patients undergoing total knee replacement. The arthroscopic image spectral data at each site were used to estimate cartilage thickness. Arthroscopically derived thickness values were compared with reference cartilage thickness as measured by 3 different methods: needle penetration, spiral computed tomography scanning, and geometric measurement after sample slicing. Results: The lowest mean error (0.28 to 0.30 mm) in the regression between arthroscopic and reference cartilage thickness was seen for reference cartilage thickness less than 1.5 mm. Corresponding values for cartilage thickness less than 2.0 and 2.5 mm were 0.32 to 0.40 mm and 0.37 to 0.47 mm, respectively. Cartilage thickness images - created by pixel-by-pixel regression model calculations applied to the arthroscopic images - were derived to demonstrate the clinical use of a camera implementation. Conclusions: On the basis of this investigation on osteoarthritic material, when one is implementing the spectroscopic method for estimating cartilage thickness into an arthroscopic camera, errors in the range of 0.28 to 0.30 mm are expected. This implementation does not, however, influence the fact that the spectral method performs less well in the cartilage thickness region from 1.5 to 2.5 mm and cannot assess cartilage thicker than 2.5 mm. Clinical Relevance: Imaging cartilage thickness directly in the arthroscopic camera video stream could serve as an interesting image tool for in vivo cartilage quality assessment, in connection with cartilage diagnosis, repair, and follow-up. © 2012 Arthroscopy Association of North America.

Cite

CITATION STYLE

APA

Johansson, A., Kuiper, J. H., Sundqvist, T., Persson, F., Speier, C., D’Alfonso, D., … Öberg, Å. (2012). Spectroscopic measurement of cartilage thickness in arthroscopy: Ex vivo validation in human knee condyles. Arthroscopy - Journal of Arthroscopic and Related Surgery, 28(10), 1513–1523. https://doi.org/10.1016/j.arthro.2012.03.009

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free