Modified loop technique in three dogs with mitral regurgitation

2Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Mitral valvuloplasty (MVP) is used in dogs with refractory mitral regurgitation (MR); however, it is difficult to tie the artificial chord, i.e., the expanded polytetrafluoroethylene suture, at the planned height of the mitral valve, because of the slippery nature of the knot. The loop technique has resolved these difficulties in humans. Premanufactured loops (length, 8.0-15.0 mm with 1.0-mm increments) were used in the new modified loop technique. In the current study, cardiac murmurs disappeared, and the MR markedly improved or completely disappeared approximately 3 months after surgery in 3 dogs. Therefore, this new technique might be effective in dogs. © 2013 The Japanese Society of Veterinary Science.

Cite

CITATION STYLE

APA

Aoki, T., Fujii, Y., Sunahara, H., Takano, H., & Wakao, Y. (2013). Modified loop technique in three dogs with mitral regurgitation. Journal of Veterinary Medical Science. https://doi.org/10.1292/jvms.11-0486