Abstract
Purpose: Regarding the high prevalence of low back pain in various communities and the\rneed to determine an appropriate treatment plan for these patients, examining their functional\rlimitation and disability level is of utmost importance. In this regard, one of the important\rindicators is Lumbar range of motion. Measurement of the range of motion is a common and\rappropriate method for determining the functional limitation of the spine and also to examine the\reffectiveness of various therapeutic interventions. This study was conducted with the purpose of\rexamining the reliability of measuring lumbar range of motion using bubble inclinometer and\rtape measure.\rMethods: This methodological study was performed on 20 healthy males (29–52 years old) and\r13 male patients with chronic non-specific low back pain (30–58 years old) in 2015. The ranges\rof lumbar forward and backward and side bending were measured with bubble inclinometer\rand rotation with tape measure for both groups. Two measurements were conducted in one day\rwith an interval of one hour to examine the within day reliability, and a third measurement was\rconducted one week later to examine the between days reliability. Statistical inference was made\rthrough calculation of intraclass correlation coefficients (ICC) and standard error of measurement\r(SEM). All data analysis was done by SPSS version 18.\rResults: The ICC and SEM values related to the within days and between days reliability were\racceptable. The within day and between days ICC range were 0.770–0.982 and 0.835–0.977,\rrespectively. SEM range was 0.38–1.20. However, the results of the reliability values of between\rdays measuring of extension in prone position, by using bubble inclinometer, in patients with\rslight low back pain were low (ICC=0.177 and SEM=5.35).\rConclusion: Results of the present study showed that measuring the lumbar range of motion\rwith bubble inclinometer and tape measure (except measuring extension in prone position by\rusing bubble inclinometer in patients with low back pain) was highly reliable. Therefore, these\r2 non-invasive and reliable tools can be used to measure the lumbar range of motion and also to\rfollow-up the effectiveness of therapeutic interventions.
Cite
CITATION STYLE
Sadeghi, R., Mosallanezhad, Z., Nodehi-Moghadam, A., Nourbakhsh, Mr., Biglarian, A., & Ezati, K. (2015). The Reliability of Bubble Inclinometer and Tape Measure in Determining Lumbar Spine Range of Motion in Healthy Individuals and Patients. Physical Treatments- Specific Physical Therapy, 5(3). https://doi.org/10.15412/j.ptj.07050303
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.