Cuff size, cuff placement, blood pressure state, anmonitoring technique can influence indirect arteriablood pressure monitoring in anesthetized bats (Pteropus vampyrus)

2Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

OBJECTIVE Evaluate agreement between 2 non-invasive blood pressure (NIBP) techniques and invasive arterial blood pressure (IBP) in anesthetized bats using various cuff sizes and cuff positioning while also evaluating its performance during hypertension and hypotension. ANIMALS 8 bats (1.1 ± 0.2 kg). PROCEDURES Bats were anesthetized with isoflurane in oxygen. NIBP was measured using oscillometric (NIBP-O) and Doppler (NIBP-D) techniques in the pectoral limb (PEC) and pelvic limbs (PEL) using 3 cuff sizes (1, 2, and 3). NIBP measurements were compared with IBP; systolic (SAPinvasive), mean (MAPinvasive), and diastolic arterial blood pressure (DAPinvasive) during normotension, hypertension, and hypotension. Hypotension was induced with isoflurane (3.8 ± 1.2%) and hypertension with norepinephrine (3 ± 0.5 µg/kg/min). Data analysis included Bland-Altman analyses and 3-way ANOVA. Results were reported as mean bias (95% CI). RESULTS NIBP-O monitor reported 29% errors, and experienced more failures with hypertension, cuff placement on PEC, and using a size 1 cuff. Across states, an agreement between NIBP-D and MAPinvasive with cuff 2 on PEL (−3 mmHg [−8, 1]), and NIBP-D and SAPinvasive with cuff 3 on PEC (2 mmHg [−5, 9 mmHg]) was achieved. NIBP-D over-estimated SAPinvasive and MAPinvasive during hypertension in both limbs with cuffs 1 and 2. Except during hypotension, NIBP-O underestimated MAPinvasive and DAPinvasive using a size 2 cuff on PEL. CLINICAL RELEVANCE In anesthetized bats, NIBP-O is unreliable for estimating IBP. NIBP-D shows acceptable agreement with MAPinvasive with cuff size 2 on PEL, and with SAPinvasive with cuff size 3 on PEC across a wide range of IBP values.

Cite

CITATION STYLE

APA

Paranjape, V. V., Gatson, B. J., Bailey, K., & Wellehan, J. F. X. (2023). Cuff size, cuff placement, blood pressure state, anmonitoring technique can influence indirect arteriablood pressure monitoring in anesthetized bats (Pteropus vampyrus). American Journal of Veterinary Research, 84(5), 1–13. https://doi.org/10.2460/ajvr.22.12.0208

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free