Computerized decision support system improves consistency of haemodynamic assessment amongst ICU team members

  • Aneman A
  • Ranganatha R
N/ACitations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction This study evaluated the potential of the NAVIGATOR (Applied Physiology) haemodynamic monitor to improve consistency of cardiovascular assessments amongst ICU members with different levels of expertise and experience. Methods Patients (n = 20) post cardiac surgery were monitored by NAVIGATOR to display heart eficiency (Eh), mean systemic f lling pressure (Pms) and vascular resistance (SVR) against targets for mean arterial pressure and cardiac output set by the clinical team. Four categories of staf participated: nine consultants (C), eight senior registrars (SR), nine registrars (R) and 11 nurses (N) (median ICU experience 15, 7, 2 and 10 years, respectively) and were asked to score Eh, Pms, and SVR ranging (discrete steps of one) from -5 (grossly subnormal) to 0 (normal) to 5 (grossly supranormal) first without (BLIND) and then given (OPEN) access to the NAVIGATOR display. Recommendations for therapeutic interventions were noted. Agreement (maximum two steps deviation for each assessment between staf ; number of patients), disagreement (median and interquartile range of steps) and therapeutic agreement (intervention/s to change Eh, Pms and SVR in similar direction/s, number of patients) were recorded and analysed for statistical difference BLIND versus OPEN (Fisher's exact test, Mann-Whitney test, P <0.05). Results Eh was commonly overestimated, Pms commonly underestimated with no clear trend for SVR. Agreement amongst all categories of staf increased and disagreement score decreased for Eh, Pms and SVR (Table 1) comparing BLIND versus OPEN assessments. Agreement for therapeutic interventions also increased significantly from 4/20 (BLIND) to 18/20 patients (OPEN). (Table Presented) Patients (n/20) and score (median and IQR). *P <0.05. Conclusion The assessment of heart function, intravascular f lling and resistance state in postoperative cardiac patients was made significantly more consistent amongst different ICU staf members using the NAVIGATOR haemodynamic monitor. Such enhanced consistency could potentially make the haemodynamic management more effective with improved clinical outcomes.

Cite

CITATION STYLE

APA

Aneman, A., & Ranganatha, R. (2013). Computerized decision support system improves consistency of haemodynamic assessment amongst ICU team members. Critical Care, 17(S2). https://doi.org/10.1186/cc12137

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free