Mimir: A Near-Infrared Wide-Field Imager, Spectrometer, and Polarimeter

  • Clemens D
  • Sarcia D
  • Grabau A
  • et al.
64Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Mimir, a new facility-class near-infrared instrument for the 1.8 m Perkins telescope on Anderson Mesa outside Flagstaff, Arizona, was commissioned and has been operating for three years. Mimir is multifunction, performing wide-field (F=5) and narrow-field (F=17) imaging, long-slit spectroscopy, and imaging polarimetry. The F=5 mode images at 0.59″ per pixel onto the 1024 × 1024 pixel ALADDIN III InSb array detector, giving a 10 0 × 10 0 field of view. In the F=17 mode, the plate scale is 0.18″ per pixel. Optically, Mimir is a refractive reimager for the F=17:5 Perkins beam. A six-lens collimator produces an achromatic 25 mm pupil, which is imaged by a five-lens camera (F=5), a four-lens camera (F=17), or a two-lens pupil viewer onto the detector. Three filter wheels precede the pupil, one follows the pupil. The wheels contain a rotating half-wave plate, broadband filters, narrowband filters, grisms, long-pass filters, a wire grid, and thermal IR blockers. The first telescope focus is within Mimir, where a slit and decker unit, consisting of two linear motion cars, selects one of 13 slit scenes. The slit and decker cars, the four filter wheels, the half-wave plate rotation, and the camera selector are all driven by stepper motors within the cold vacuum space. Cooling is provided by a CTI 1050 two-stage, closed-cycle helium refrigerator, keeping the optics, filters, and internal surfaces between 65 and 75 K and the detector at 33.5 K. Switching between Mimir's different modes takes only a few seconds, making it a versatile tool for conducting a wide range of investigations and for quickly reacting to changing observing conditions. Mimir on the Perkins telescope achieves imaging sensitivities 2-4 mag deeper than 2MASS, moderate resolution (R ∼ 700) JHK spectra of virtually any 2MASS source, high-precision wide-field imaging polarimetry, and L 0 and M 0 band imaging and spectroscopy.

Cite

CITATION STYLE

APA

Clemens, D. P., Sarcia, D., Grabau, A., Tollestrup, E. V., Buie, M. W., Dunham, E., & Taylor, B. (2007). Mimir: A Near-Infrared Wide-Field Imager, Spectrometer, and Polarimeter. Publications of the Astronomical Society of the Pacific, 119(862), 1385–1402. https://doi.org/10.1086/524775

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free