Abstract
Introduction Diffusion Tensor MRI (DT-MRI) is a promising tool for the evaluation of brachial plexus pathology. Therefore, we introduce and evaluate a fast DT-MRI protocol (8min33s scanning with 5–10 min postprocessing time) for the brachial plexus. Materials and methods Thirty healthy volunteers within three age-groups (18–35, 36–55, and > 56) received DT-MRI of the brachial-plexus twice. Means of fractional-anisotropy (FA), mean-diffusivity (MD), axial-diffusivity (AD), and radial-diffusivity (RD) for the individual roots and trunks were evaluated. A stepwise forward approach was applied to test for correlations with age, sex, body-mass-index (BMI), bodysurface, height, and bodyweight. Within-subject, intra-rater, and inter-rater repeatability were assessed using Bland-Altman analysis, coefficient of variation (CV), intraclass-correlation (ICC), and minimal detectable difference (MDD). Results No differences between sides and root levels were found. MD, AD, and RD correlated (P < 0.05) with bodyweight. Within-subject quantification proved repeatable with CVs for FA, MD, AD, and RD of 16%, 12%, 11%, and 14%, respectively. Discussion The DT-MRI protocol was fast and repeatable. Found correlations should be considered in future studies of brachial plexus pathology.
Cite
CITATION STYLE
Oudeman, J., Verhamme, C., Engbersen, M. P., Caan, M. W. A., Maas, M., Froeling, M., … Strijkers, G. J. (2018). Diffusion tensor MRI of the healthy brachial plexus. PLoS ONE, 13(5). https://doi.org/10.1371/journal.pone.0196975
Register to see more suggestions