Flow characteristics and stress analysis of a Parallel Gate Valve

10Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

Gate valves have been widely used in the piping system and have attracted a lot of attention from researchers. In this paper, a wedge-type double disk parallel gate valve is chosen to be analyzed. The Reynolds number varying from 200 to 500,000, and the valve opening degree varying from 20% to 100%, and the groove depth varying from 2.3 mm to 9 mm are chosen to investigate their effects on the flow and loss coefficients of the gate valve. The results show that the loss coefficient decreases and the flow coefficient increases with the increase of the Reynolds number and the valve opening degree, while with the increase of the groove depth, the loss coefficient barely changes, but the flow coefficient increases if the Reynolds number is larger than 10,000. In addition, the effects of the gaps between the disk and the limit stop on the stress distribution of the bolt are also investigated, and the results show that if the gaps are negative, high stress will act on the bolt at the contact position between the bolt and the limit stop.

Cite

CITATION STYLE

APA

Wu, H., Li, J. Y., & Gao, Z. xin. (2019). Flow characteristics and stress analysis of a Parallel Gate Valve. Processes, 7(11). https://doi.org/10.3390/pr7110803