Characterization of residual conduction gaps after hotballoon-based antral ablation of atrial fibrillation: Evidence From Ultra-High-Resolution 3-Dimensional Mappin

12Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

Background: The electrophysiological characteristics of residual conduction gaps between the left atrium (LA) and pulmonary veins (PVs) after HotBalloon-based wide antral ablation (HBWA) of atrial fibrillation (AF) remain incompletely understood. This study aimed to characterize the residual gaps by means of ultra-high-resolution mapping. Methods and Results: A total of 55 AF patients underwent HBWA by a predetermined protocol (6-shot total-based antral approach). LA-PV maps were created using 64-electrode minibasket catheters. In total, 55 residual gaps were identified among 26 (47%) patients. Residual gaps included 33 left superior (LS: 60%), 10 left inferior (18%), 6 right superior (11%), and 6 right inferior (11%) PVs. Those gaps demonstrated both extremely lower bipolar amplitudes (0.11 [interquartile range: 0.06–0.27] mV) and conduction velocities (0.75±0.27 m/s); however, the length was confined (10.3±4.1 mm) except for the LSPV anterior carina (12.2±2.4 mm) region. Among the carina regions, all gaps had far-field potentials consistently added to the PV potentials. Left atrial appendage pacing to split the far-field activity identified confined gap regions (6.7±1.9 mm). Touch-up ablation eliminated the residual PV potentials in all cases. Conclusions: HBWA resulted in a certain degree of residual gap conduction in particular antral regions. These gaps exhibited narrow lengths with lower amplitudes, and often had far-field recordings from the left atrial appendage. Combined with pacing maneuvers, ultra-high-resolution activation maps could both visualize all confined gaps and ensure a bare minimum of touch-up ablations in all patients with gap conduction.

Cite

CITATION STYLE

APA

Nakahara, S., Hori, Y., Fukuda, R., Nishiyama, N., Kobayashi, S., Sakai, Y., & Taguchi, I. (2019). Characterization of residual conduction gaps after hotballoon-based antral ablation of atrial fibrillation: Evidence From Ultra-High-Resolution 3-Dimensional Mappin. Circulation Journal, 83(6), 1206–1213. https://doi.org/10.1253/circj.CJ-18-1051

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free