Comparison of geometric design, metallurgical features and mechanical behavior of ProTaper Gold SX and two replica-like instruments

1Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Objectives: To assess the characteristics, performance, and safety of ProTaper Gold SX (PTG SX) replica-like instruments. Methods: A multimethod research involving the assessment of geometric design (macro and through scanning electron microscope), Ti/Ni proportions (energy-dispersive X-ray spectroscopy), phase transformation temperatures (differential scanning calorimetry), torsional resistance, and flexibility was conducted to compare two SX replica-like instruments (Premium Taper Gold and Go-Taper Flex) with the original PTG SX. Results were compared using one-way ANOVA with post hoc Tukey or Kruskal-Wallis tests according to gaussian or non-gaussian distribution (Shapiro-Wilk test). The significance level was set at 0.05. Results: The three SX instruments have nine cutting blades with helix angles of approximately 21°, symmetrical blade geometry without radial lands, a convex triangular cross-section design, and near equiatomic Ti/Ni atomic proportions. Design differences were observed at the tip geometry and surface finishing, which was smoother in the Premium Taper Gold and irregular in the Go-Taper Flex. Distinct R-phase start (Rs) and finish (Rf) phase transformation temperatures were noted between PTG (Rs ~48°C and Rf ~30°C), Go-Taper Flex (Rs ~43°C and Rf ~25°C), and Premium Taper Gold (Rs ~30°C and Rf ~15°C). In the mechanical tests, Go-Taper Flex presented lower maximum torque (mean 0.5 N.cm) and higher bending resistance (mean 582.2 gf) (less flexibility) than PTG (means 0.8 N.cm and 447.1 gf) (P<0.05). No significant differences were observed in the mechanical tests between Premium Taper Gold and PTG (P>0.05). Conclusions: Overall, the tested replica-like systems showed different features compared to the original PTG SX instrument.

Cite

CITATION STYLE

APA

Martins, J. N. R., Silva, E. J. N. L., Marques, D., Arantes-Oliveira, S., Caramês, J., & Versiani, M. A. (2021). Comparison of geometric design, metallurgical features and mechanical behavior of ProTaper Gold SX and two replica-like instruments. Revista Portuguesa de Estomatologia, Medicina Dentaria e Cirurgia Maxilofacial, 62(1), 1–8. https://doi.org/10.24873/j.rpemd.2021.01.817

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free