Operation of a single-phase autonomous inverter as a part of a low-power wind complex

34Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

The article discusses the experience of operating a wind power complex with a low-power wind power installation (5 kW), the use of which is promising for powering remote oil production facilities, exploration and other types of mining operations. The structure of the studied complex and its characteristics, technical problems that have arisen during operation for 6 years are given. The elements of the wind energy complex – the battery charge regulator and the inverter-converter are considered. The consequences of the mechanical regulator failure of battery charge are considered and recommendations for its replacement are presented. The issues of diagnostics and repair of one of the main elements of the complex – the inverter-converter, its component – DC link are highlighted in detail. Oscil-lograms of the output voltage of the inverter-converter are presented for different capacities of the DC link and the images of the repaired inverter-converter are given. Recommendations are given on choosing an inverter-converter and setting up the operating modes of the wind energy complex.

Cite

CITATION STYLE

APA

Belsky, А., Dobush, V. S., & Haikal, S. F. (2019). Operation of a single-phase autonomous inverter as a part of a low-power wind complex. Journal of Mining Institute, 239, 564–569. https://doi.org/10.31897/PMI.2019.5.564