PQ improvement of micro-grid by using DG and power quality conditioner with BESS

1Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

DG Grid interfaced system has been focused through this paper. The objective is to improve power quality of the grid, which was pollut-ed by various means. The improvement of power quality of the micro grid includes uses of a specially designed DG, BESS and Power Quality conditioner. The system consists of a two-stage power conversion. Solar PV supplies power for both DC and AC loads. Manu-facturer datasheet is used for modeling the PV panel. In order to keep the BUS voltage stable a BESS is joined to DC BUS through pow-er electronic converter, which is used to absorb the excess power whenever production is high and deliver power to the load on low pro-duction. The system continues to supply the local loads, incase of grid discontinuity. Thus it eliminates threats of islanding. This paper also focuses on control and stability of DC bus voltage and energy management scheme. The project uses Matlab/Simulink platform for efficient verification. For power quality improvement of Micro Grid it uses 3leg inverter, which is coupled with SPV and MPPT with Battery storage, which is used as compensator for the whole system. For prevention to reduce voltage current and power flow between DG and Grid, it is necessary to have an optimum control. Through the adjustment of power circulation between shunt paired DG ensures current voltage and power on micro grid. +ve, -ve and Zero sequence components of currents and voltage can be adjusted by the sug-gested methodology in Grid tied DG system. The said PQC have multiple uses. Firstly as a power converter and secondly as a shunt APF for harmonic compensation on voltage, current and power (both active and reactive) for both balanced and unbalanced loads in the Grid tied DG system. It also cares for the neutral conductor. Either individually or in grid connected mode all the above objectives can be achieved. For the entire Grid, it is realized that after compensation three phase four wired un-balance loads looks as balanced linear resis-tive load for the Grid. All these task significantly replicated on MATLAB/Simulink. After compensation the total harmonic distortion on input voltage and current reduced drastically. IEEE519 in the range of 5% suitably accepts it.

Cite

CITATION STYLE

APA

Mishra, C. S., Jena, R. K., & Nayak, S. R. (2018). PQ improvement of micro-grid by using DG and power quality conditioner with BESS. International Journal of Engineering and Technology(UAE), 7(2.32 Special Issue  32), 245–252. https://doi.org/10.14419/ijet.v7i2.32.15577

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free