Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis

15Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Echocardiography (2DE) is integral for screening and longitudinal evaluation of pulmonary arterial hypertension (PAH) in systemic sclerosis (SSc). In the present study, we sought to establish the reliability, repeatability, and reproducibility of 2DE parameters in SSc patients with and without PAH and to define the minimal detectable difference (MDD), the smallest change detected beyond measurement error. Methods: SSc patients without known PAH and with invasively confirmed PAH on stable therapies underwent 2DE with strain at two time points. Analysis of variance (ANOVA) and coefficients of variation (CV) were calculated to assess for repeatability, reliability, and reproducibility. Intra- and inter-observer agreement were assessed using intraclass correlation. Bland-Altman analysis explored the level of agreement between evaluations. MDD was calculated using the standard error of measurement for each parameter by cohort. Results: ANOVA demonstrated few significant differences between evaluations across groups. Global right ventricular longitudinal systolic strain (GRVLSS, 9.7%) and fractional area change (FAC, 21.3%) had the largest CV, while tricuspid annular plane excursion (TAPSE), S’ wave, and right ventricular outflow track velocity time integral (RVOT VTI) were 0.87%, 3.2%, and 6.0%, respectively. Intra- and inter-observer agreement was excellent. MDD for TAPSE, FAC, S’ wave, RVOT VTI, GRVLSS, and RVSP were 0.11 cm, 0.03%, 1.27 cm/s, 0.81 cm, 1.14%, and 6.5 mmHg, respectively. Conclusions: We demonstrate minimal measurement error in clinically important 2DE-based measures in SSc patients with and without PAH. Defining the MDD in this population has important implications for PAH screening, assessment of therapeutic response, and sample size calculations for future clinical trials.

Cite

CITATION STYLE

APA

Mukherjee, M., Mercurio, V., Balasubramanian, A., Shah, A. A., Hsu, S., Simpson, C. E., … Mathai, S. C. (2022). Defining minimal detectable difference in echocardiographic measures of right ventricular function in systemic sclerosis. Arthritis Research and Therapy, 24(1). https://doi.org/10.1186/s13075-022-02835-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free