Construction of a Newly Designed Small-Size Mass Spectrometer for Helium Isotope Analysis: Toward the Continuous Monitoring Of 3He/4He Ratios In Natural Fluids

  • Bajo K
  • Sumino H
  • Toyoda M
  • et al.
N/ACitations
Citations of this article
31Readers
Mendeley users who have this article in their library.

Abstract

The construction of a small-size, magnetic sector, single focusing mass spectrometer (He-MS) for the continuous, on-site monitoring of He isotope ratios ((3)He/(4)He) is described. The instrument is capable of measuring (4)He/(20)Ne ratios dissolved in several different types of natural fluids of geochemical interest, such as groundwater and gas from hot springs, volcanoes and gas well fields. The ion optics of He-MS was designed using an ion trajectory simulation program "TRIO," which permits the simultaneous measurement of (3)He and (4)He with a double collector system under a mass resolution power (M/ΔM) of >700. The presently attained specifications of He-MS are; (1) a mass resolving power of ca. 430, sufficient to separate (3)He(+) from interfering ions, HD(+) and H3 (+), (2) ultra-high vacuum conditions down to 3×10(-8) Pa, and (3) a sufficiently high sensitivity to permit amounts of (3)He to be detected at levels as small as 10(-13) cm(3) STP (3×10(6) atoms). Long term stability for (3)He/(4)He analysis was examined by measuring the (3)He/(4)He standard gas (HESJ) and atmospheric He, resulting in ∼3% reproducibility and ≤5% experimental error for various amounts of atmospheric He from 0.3 to 2.3×10(-6) cm(3) STP introduced into the instrument. A dynamic range of measurable (3)He/(4)He ratios with He-MS is greater than 10(3) which was determined by measuring various types of natural fluid samples from continental gas (with a low (3)He/(4)He ratio down to 2×10(-8)) to volcanic gas (with a high (3)He/(4)He ratio up to 3×10(-5)). The accuracy and precision of (3)He/(4)He and (4)He/(20)Ne ratios were evaluated by comparing the values with those measured using well established noble gas mass spectrometers (modified VG5400/MS-III and -IV) in our laboratory, and were found to be in good agreement within analytical errors. Usefulness of the selective extraction of He from water/gas using a high permeability of He through a silica glass wall at high temperature (700°C) is demonstrated.

Cite

CITATION STYLE

APA

Bajo, K., Sumino, H., Toyoda, M., Okazaki, R., Osawa, T., Ishihara, M., … Nagao, K. (2012). Construction of a Newly Designed Small-Size Mass Spectrometer for Helium Isotope Analysis: Toward the Continuous Monitoring Of 3He/4He Ratios In Natural Fluids. Mass Spectrometry, 1(2), A0009–A0009. https://doi.org/10.5702/massspectrometry.a0009

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free