An in vitro investigation comparing methods of minimizing excess luting agent for cement-retained implant-supported fixed partial dentures

9Citations
Citations of this article
49Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Statement of problem: The use of cement-retained implant-supported prostheses is a well-established treatment option. Techniques have been proposed to reduce the amount of residual excess cement (REC) around cement-retained single-implant restorations. However, studies evaluating the effectiveness of such techniques related to cement-retained implant-supported fixed partial dentures (CRISFPDs) are lacking. Purpose: The purpose of this in vitro study was to evaluate the effectiveness of various cement application techniques for CRISFPDs. Material and methods: Two implant analogs were placed in the lateral incisor sites in a maxillary, 3D printed cast with 4 missing incisors. Twenty standardized, removable, printed soft-tissue replicas, 40 milled titanium custom abutments, and 20 milled zirconia CRISFPDs were fabricated. Two cement application techniques, the brush on technique (BOT), and the polyvinyl siloxane index (PI) technique were compared. Two cementation techniques, without bib (control) (n=10) and with a polytetrafluoroethylene (PTFE) bib (test) (n=10), were used. A premeasured amount of interim cement was used to cement the CRISFPDs. The CRISFPDs were retrieved after cementation, and standardized photographs of 4 quadrants of each abutment-CRISFPD assembly were made by using a software program that is used to calculate the ratio between the area covered with REC and the total specimen area. The extension of the REC on both the abutment and soft-tissue replica was measured at sites before and after cleaning the REC. A generalized linear mixed-model procedure was used for statistical analysis (α=.05). Results: For cement application, the polyvinyl siloxane (PVS) index technique had significantly less REC than the brush on technique (P

Cite

CITATION STYLE

APA

Bukhari, S. A., AlHelal, A., Kattadiyil, M. T., Wadhwani, C. P. K., Taleb, A., & Dehom, S. (2020). An in vitro investigation comparing methods of minimizing excess luting agent for cement-retained implant-supported fixed partial dentures. Journal of Prosthetic Dentistry, 124(6), 706–715. https://doi.org/10.1016/j.prosdent.2019.11.016

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free