The time-resolved fluorescence-based PCA3 test on urinary sediments after digital rectal examination; a Dutch multicenter validation of the diagnostic performance

165Citations
Citations of this article
78Readers
Mendeley users who have this article in their library.

Abstract

Purpose: To improve the specificity in prostate cancer diagnosis and to prevent unnecessary prostate biopsies, especially in the serum prostate-specific antigen (PSA) "gray zone" between 3 and 15 ng/mL, the implementation of prostate cancer-specific markers is urgently needed. The recently discovered prostate cancer antigen 3 (PCA3) is such a promising prostate cancer marker. In a previous single institution study, the PCA3 urine test clearly proved to be of diagnostic value. Therefore, the diagnostic performance of the PCA3 urine test was validated in a multicenter study. Experimental Design: The first voided urine after digital rectal examination was collected from a total of 583 men with serum PSA levels between 3 and 15 ng/mL who were to undergo prostate biopsies. We determined the PCA3 score in these samples and correlated the results with the results of the prostate biopsies. Results: A total of 534 men (92%) had an informative sample. The area under the receiver-operating characteristic curve, a measure of the diagnostic accuracy of a test, was 0.66 for the PCA3 urine test and 0.57 for serum PSA. The sensitivity for the PCA3 urine test was 65%, the specificity was 66% (versus 47% for serum PSA), and the negative predictive value was 80%. Conclusions: In this multicenter study, we validated the diagnostic performance of the PCA3 urine test in the largest group studied thus far using a PCA3 gene-based test. This study shows that the PCA3 urine test, when used as a reflex test, can improve the specificity in prostate cancer diagnosis and could prevent many unnecessary prostate biopsies. © 2007 American Association for Cancer Research.

Cite

CITATION STYLE

APA

Van Gils, M. P. M. Q., Hessels, D., Van Hooij, O., Jannink, S. A., Peelen, W. P., Hanssen, S. L. J., … Schalken, J. A. (2007). The time-resolved fluorescence-based PCA3 test on urinary sediments after digital rectal examination; a Dutch multicenter validation of the diagnostic performance. Clinical Cancer Research, 13(3), 939–943. https://doi.org/10.1158/1078-0432.CCR-06-2679

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free