Geometric changes in ventriculoaortic complex after transcatheter aortic valve replacement and its association with post-procedural prosthesis-patient mismatch: An intraprocedural 3D-TEE study

7Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

Abstract

Prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) leads to increased mortality. However, its peri-procedural determinants remain unknown. We investigated geometric changes in aortic annulus (AoA) and left ventricular outflow tract (LVOT) during TAVR by three-dimensional transoesophageal echocardiography (3D-TEE) and its association with post-procedural PPM. Methods and results A total of 131 patients with severe aortic stenosis underwent intraprocedural 3D-TEE during balloon-expandable TAVR. The severity of PPM was graded using the indexed effective orifice area calculated by Doppler echocardiography at discharge, with moderate defined as ≥0.65 and ≤0.85 cm2/m2 and severe defined as ,0.65 cm2/m2. 3D planimetered AoA area decreased after TAVR (P , 0.001), whereas the LVOT increased (P = 0.004). The eccentricity of both AoA and LVOT decreased after TAVR (both, P , 0.001). At discharge, the incidence of overall and severe PPM was 44 and 12%, respectively. Patients with PPM had a larger body surface area, smaller aortic valve area, and less frequent balloon dilation (all P , 0.05). Patients with PPM had a lower post-TAVR AoA area/pre-TAVR AoA area (91+8 vs. 95+7%, P = 0.001) than those without PPM. The post-TAVR AoA area/pre-TAVR AoA area was independently associated with overall PPM (odds ratio, 1.80; 95% CI, 1.06-3.05; P = 0.031) and severe PPM (odds ratio, 2.50; 95% CI, 1.05-5.36; P = 0.04). Additionally, a cut-off value of this ratio .86.3% had a sensitivity of 84% and a specificity of 44% for the prevention of severe PPM. Conclusion 3D-TEE can evaluate geometric changes in AoA and LVOT during balloon-expandable TAVR and predicts postprocedural PPM.

Cite

CITATION STYLE

APA

Utsunomiya, H., Mihara, H., Itabashi, Y., Kobayashi, S., Siegel, R. J., Chakravarty, T., … Shiota, T. (2017). Geometric changes in ventriculoaortic complex after transcatheter aortic valve replacement and its association with post-procedural prosthesis-patient mismatch: An intraprocedural 3D-TEE study. European Heart Journal Cardiovascular Imaging, 18(1), 1–10. https://doi.org/10.1093/ehjci/jew039

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free