Mass-spectrometry-based quantitation of Her2 in gastroesophageal tumor tissue: comparison to IHC and FISH

37Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Trastuzumab has shown a survival benefit in cases of Her2-positive gastroesophageal cancer (GEC). Immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH) currently determine eligibility for trastuzumab-based therapy. However, these low-throughput assays often produce discordant or equivocal results. Methods: We developed a targeted proteomic assay based on selected reaction monitoring mass spectrometry (SRM-MS) and quantified levels (amol/μg) of Her2-SRM protein in cell lines (n = 27) and GEC tissues (n = 139). We compared Her2-SRM protein expression with IHC/FISH, seeking to determine optimal SRM protein expression cutoffs in order to identify HER2 gene amplification. Results: After demonstrating assay development, precision, and stability, Her2-SRM protein measurement was observed to be highly concordant with the HER2/CEP17 ratio, particularly in a multivariate regression model adjusted for SRM expression of the covariates Met, Egfr, Her3, and HER2 heterogeneity, as well as their interactions (cell lines r2 = 0.9842; FFPE r2 = 0.7643). In GEC tissues, Her2-SRM protein was detected at any level in 71.2 % of cases. ROC curves demonstrated that Her2-SRM protein levels have a high specificity (100 %) at an upper-level cutoff of >750 amol/µg and sensitivity of 75 % at a lower-level cutoff of <450 amol/μg for identifying HER2 FISH-amplified tumors. An “equivocal zone” of 450–750 amol/µg of Her2-SRM protein was analogous to IHC2+ but represented fewer cases (9–16 % of cases versus 36–41 %). Conclusions: Compared to IHC, targeted SRM-Her2 proteomics provided more objective and quantitative Her2 expression with excellent HER2/CEP17 FISH correlation and fewer equivocal cases. Along with its multiplex capability for other relevant oncoproteins, these results demonstrate a refined HER2 protein expression assay for clinical application.

Cite

CITATION STYLE

APA

Catenacci, D. V. T., Liao, W. L., Zhao, L., Whitcomb, E., Henderson, L., O’Day, E., … Hembrough, T. (2016). Mass-spectrometry-based quantitation of Her2 in gastroesophageal tumor tissue: comparison to IHC and FISH. Gastric Cancer, 19(4), 1066–1079. https://doi.org/10.1007/s10120-015-0566-0

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free