Development and Validation of Non simultaneous Retinal Image Acquisition-Based Retinal Oximeter

0Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The purpose of this study was to develop and validate a tool for the measurement of retinal oxygen saturation using a conventional fundus camera-based nonsimultaneous imaging technique. Retinal oximetry setup comprising a conventional Zeiss FF450IR fundus camera, dual wavelength band-pass filters of wavelengths 570 and 600 nm were used. Image analysis was performed using MATLAB R2013b. All the study participants underwent comprehensive eye examination, fundus examination, complete hemogram analysis, and evaluation of systemic hemodynamics. Fundus images were captured by a nonsimultaneous retinal oximetry. A total of 45 subjects were included in the analysis. Median age of the subjects was 21 years ranging from 19 to 34 years. The median retinal arteriolar and venular oxygen saturation was 94.7% and 55.8%. Comparison of retinal oxygen saturation between three visits showed no statistically significant difference for both arteriolar (p = 0.33)and venular oxygen saturation (p = 0.79). Intraclass correlation coefficients for test-retest, short-term, and day-to-day repeatability were 0.84, 0.90, and 0.86 for arteriolar oxygen saturation and 0.92, 0.98, and 0.98 for retinal venular oxygen saturation. Oxygen saturation in retinal arteriolar and venular blood vessels can be measured by nonsimultaneous image acquisition technique using a conventional fundus camera with good repeatability.

References Powered by Scopus

Automatic retinal oximetry

255Citations
N/AReaders
Get full text

Retinal vessel oxygen saturation in healthy individuals

210Citations
N/AReaders
Get full text

Retinal oxygen saturation is altered in diabetic retinopathy

201Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Singh, S., Velu, G., & Raman, R. (2017). Development and Validation of Non simultaneous Retinal Image Acquisition-Based Retinal Oximeter. Scientific Reports, 7(1). https://doi.org/10.1038/s41598-017-04085-x

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Professor / Associate Prof. 1

33%

Readers' Discipline

Tooltip

Engineering 2

40%

Agricultural and Biological Sciences 1

20%

Pharmacology, Toxicology and Pharmaceut... 1

20%

Neuroscience 1

20%

Save time finding and organizing research with Mendeley

Sign up for free