Improving Care with the First measurement of high-sensitivity troponin T (ICare-FirsT) to enable early rule out and reduce length of stay: A diagnostic and observational study

3Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background Pathways incorporating clinical risk assessment, ECG and serial troponin measurements for the assessment of patients with possible myocardial infarction (MI) in the ED are standard practice. Incorporating a single troponin test to stratify to low risk of MI using a baseline measurement of cardiac troponin (cTn) with a high-sensitivity T assay (hs-cTnT) is recommended. We aimed to implement a pathway incorporating a single-test component and measure the impact on length of stay (LOS). Methods There were two study phases: (1) Development and performance assessment of a novel pathway incorporating a single-test hs-cTnT stratification using high-fidelity research data, (2) An audit of the implementation of a single-test Roche hs-cTnT strategy within multiple EDs. The low-risk threshold used for hs-cTnT was 5 ng/L. The safety metric was MI or death not known to be non-cardiac within 30 days (MACE30). Results Phase I: The derived pathway had 16.3% low risk after one blood draw ≥3 hours from symptom onset with hs-cTnT <5 ng/L, non-ischaemic ECG and ED Assessment of Chest pain Score <21. Phase II: In six hospitals, there were 10 912 patients in the control arm and 13 997 after implementation of single-test hs-cTnT. The unadjusted estimated mean reduction in LOS after intervention was 1.6% (95% CI 0.4% to 2.9%). After adjustment accounting for increased presentations, this was 8.5% (95% CI 7.7% to 9.3%). Conclusions Within clinical pathways, a single test with a result from an hs-cTnT of <5 ng/L as a component resulted in a small, but meaningful, reduction in mean ED LOS.

Cite

CITATION STYLE

APA

Pickering, J. W., Joyce, L., Devlin, G., Pemberton, C., Troughton, R., Richards, A. M., & Than, M. P. (2025). Improving Care with the First measurement of high-sensitivity troponin T (ICare-FirsT) to enable early rule out and reduce length of stay: A diagnostic and observational study. Emergency Medicine Journal, 42(9), 579–584. https://doi.org/10.1136/emermed-2024-214754

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free