Comparison of drop size distribution parameter (D0) and rain rate from S-band dual-polarized ground radar, TRMM precipitation radar (PR), and combined PR-TMI: Two events from Kwajalein Atoll

21Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The estimation of the drop size distribution parameter [median volume diameter (D0)] and rain rate (R) from the Tropical Rainfall Measuring Mission (TRMM) precipitation radar (PR) as well as from combined PR-TRMM Microwave Imager (TMI) algorithms are considered in this study for two TRMM satellite overpasses near theKwajaleinAtoll. An operational dual-polarized S-band radar (KPOL) located inKwajalein is central as the only TRMM ground validation site for measurement of precipitation over the open ocean. The accuracy of the TRMMPR in retrieving D0 and R is better for precipitation over the ocean based on a more stable surface reference technique for estimating the path-integrated attenuation. Also, combined PR-TMI methods are more accurate over the open ocean because of better knowledge of the surface microwave emissivity. Using Zh (horizontal polarized radar reflectivity) and Zdr (differential reflectivity) data for the two TRMM overpass events over Kwajalein, D0 and R from KPOL are retrieved. Herein, the main objective is to see if the D0 retrieved from either PR or the combined PR-TMI algorithms are in agreement with KPOL-derived values. Also, the variation of D0 versus R is compared for convective rain pixels from KPOL, PR, and PR-TMI. It is shown that the PR-TMI optimal estimation scheme does indeed adjust the D0 in the "correct"direction, on average, from the a priori state if the KPOL data are considered to be the ground truth. This correct adjustment may be considered as evidence of the value added by the TMI brightness temperatures in the combined PR-TMI variational scheme, at least for the two overpass events considered herein. © 2012 American Meteorological Society.

Author supplied keywords

Cite

CITATION STYLE

APA

Bringi, V. N., Huang, G. J., Munchak, S. J., Kummerow, C. D., Marks, D. A., & Wolff, D. B. (2012). Comparison of drop size distribution parameter (D0) and rain rate from S-band dual-polarized ground radar, TRMM precipitation radar (PR), and combined PR-TMI: Two events from Kwajalein Atoll. Journal of Atmospheric and Oceanic Technology, 29(11), 1603–1616. https://doi.org/10.1175/JTECH-D-11-00153.1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free