Understanding the behavior of Li-ion cells during thermal runaway is critical to evaluate the safety of these energy storage devices under outstanding conditions. Li-ion cells possess a high energy density and are used to store and supply energy to many aerospace applications. Incidents related to the overheating or thermal runaway of these cells can cause catastrophic damages that could end up costly space missions; therefore, thermal studies of Li-ion cells are very important for ensuring safety and reliability of space missions. This work evaluates the thermal behavior of Li-ion cells before and after storage degradation at high temperature using accelerating rate calorimeter (ARC) equipment to analyze the thermal behavior of Li-ion cells under adiabatic conditions. Onset temperature points of self-heating and thermal runaway reactions are obtained. The onset points are used to identify non-self-heating, self-heating and thermal runaway regions as a function of state of charge. The results obtained can be useful to develop accurate thermo-electrochemical models of Li-ion cells.
CITATION STYLE
Mendoza-Hernandez, O. S., Taniguchi, S., Ishikawa, H., Tanaka, K., Fukuda, S., Sone, Y., & Umeda, M. (2017). Accelerating Rate Calorimetry Tests of Lithium-Ion Cells before and after Storage Degradation at High Temperature. In E3S Web of Conferences (Vol. 16). EDP Sciences. https://doi.org/10.1051/e3sconf/20171607001