Fabrication and Diffraction Efficiency of a Large-format, Replicated X-Ray Reflection Grating

  • Miles D
  • McCoy J
  • McEntaffer R
  • et al.
70Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

We present the methodology used to fabricate an X-ray reflection grating and describe a technique for grating replication. Further, we present the experimental procedure and results of a study to measure the diffraction efficiency of a replicated X-ray reflection grating in an extreme off-plane geometry. The blazed grating demonstrates a total diffraction efficiency of ∼60% from 0.34 to 1.2 keV at a grazing angle of ∼1.°5, with single-order efficiency ranging from ∼35% to 65% for energies within the blaze envelope. The diffraction efficiency of the grating measured relative to the reflectivity of the metal coating averages ∼90% above 0.34 keV. Data collected as a function of beam position on the grating indicate a relative variation in total efficiency of <1% rms across the grating surface.

Cite

CITATION STYLE

APA

Miles, D. M., McCoy, J. A., McEntaffer, R. L., Eichfeld, C. M., Lavallee, G., Labella, M., … Steiner, T. (2018). Fabrication and Diffraction Efficiency of a Large-format, Replicated X-Ray Reflection Grating. The Astrophysical Journal, 869(2), 95. https://doi.org/10.3847/1538-4357/aaec73