Abstract
Patients with type 1 diabetes mellitus (T1D) require insulin administration at all times to maintain euglycemia and metabolic stability. Insulin administration in the perioperative period is complicated by fasting requirements and perioperative stressors that can change the patient's insulin needs. In addition, many anesthesia providers are not familiar with insulin dosing strategies and technology, such as insulin pumps and continuous glucose monitors (CGMs), that are commonly used by patients with T1D. Errors in perioperative insulin administration can lead to hypoglycemia, hyperglycemia, and diabetic ketoacidosis. This article reviews common errors of associated with the perioperative management of patients with T1D, including failure to assess and coordinate patient care preoperatively; failure to understand diabetes management and technology; failure to monitor blood glucose and recognize dysglycemia; and failure to appropriately administer basal insulin.
Author supplied keywords
Cite
CITATION STYLE
Hoagland, M., Duggar, B., Hamrick, J., Alonso, G. T., & Martin, L. (2024, January 1). Error traps in the perioperative management of children with type 1 diabetes. Paediatric Anaesthesia. John Wiley and Sons Inc. https://doi.org/10.1111/pan.14763