Haemodynamic flow abnormalities in bicuspid aortic valve disease improve with aortic valve replacement

  • Bissell M
  • Loudon M
  • Hess A
  • et al.
N/ACitations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Bicuspid aortic valve disease (BAV) is associated with dilatation of the proximal aorta and abnormal flow patterns, particularly increased helical flow and changes in the aortic wall shear stress. These altered flow patterns may be partly responsible for the aortic dilation, though the aetiology is still unclear. Aortic valve replacement can modify the flow pattern in the proximal aorta (potentially to normal) and could thus have an effect on future aortic dilation. In this study, we aimed to assess the effect of different types of aortic valve replacement (AVR) on aortic flow patterns. Methods: We prospectively enrolled 69 participants: 23 BAV patients with prior AVR (10 mechanical, 6 bioprosthetic, 7 Ross procedure), 23 BAV patients with a native aortic valve and 23 healthy volunteers. All underwent 4D flow cardiovascular magnetic resonance. Results: The majority of patients with mechanical AVR or Ross showed a normalised flow pattern (70% and 57% respectively) with near normal rotational flow values (7.4+/-3.9 and 11.0+/-12.0mm2/s respectively; normal range -5 to +11 mm2/s); and reduced in-plane wall shear stress compared to native BAV (0.13+/-0.18N/m2 for mechanical AVR vs. 0.37+/-0.26N/m2 for native BAV, p<0.05). In contrast, all subjects with bioprosthetic AVR showed abnormal flow patterns (mainly marked right-handed helical flow), with similar rotational flow values to native BAV (25.3+/-15.0mm2/s and 20.1+/-11.0mm2/s respectively, p>0.05) and similar wall shear stress pattern. Data before and after AVR (n=13) supported these findings: mechanical AVR showed a significant reduction in rotational flow (29.3+/-15.1 to 7.9+/-4.2mm2/s, p<0.05) and in-plane wall shear stress (0.45+/-0.19 to 0.20+/-0.12N/m2, p<0.05), whereas these remained unchanged in the bioprosthetic AVR group. Conclusions: Abnormal flow patterns in BAV are significantly reduced after mechanical AVR or Ross procedure, but remain similar after bioprosthetic AVR. This is the first insight indicating that type of valve replacement may influence post-operative flow patterns, and could have important implications for future aortic growth. (Figure Presented).

Cite

CITATION STYLE

APA

Bissell, M. M., Loudon, M., Hess, A. T., Stoll, V., Orchard, E., Neubauer, S., & Myerson, S. G. (2015). Haemodynamic flow abnormalities in bicuspid aortic valve disease improve with aortic valve replacement. Journal of Cardiovascular Magnetic Resonance, 17, P330. https://doi.org/10.1186/1532-429x-17-s1-p330

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free