Combination of different noninvasive measuring techniques: a new approach to increase accuracy of peripheral near infrared spectroscopy

  • Pichler G
  • Grossauer K
  • Peichl E
  • et al.
23Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

Abstract

One of the problems of near-infrared-spectroscopy (NIRS) measurements is low reproducibility. The aim of the present study was to introduce quality criteria to increase reproducibility of peripheral NIRS measurements. In a prospective cohort study in 40 neonates, repeated NIRS measurements were performed on the calf. During five "reapplication" periods (of NIRS optodes), five "measurements" (venous occlusions) were performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO2), fractional oxygen extraction (FOE), hemoglobin flow (Hbflow), oxygen delivery (DO2), and oxygen consumption (VO2) were assessed. Measurements with linear changes during venous occlusions were included for further analysis (first quality criterion: R 20.95). The second quality criterion was the equation 0≤TOI-SvO2≤(SaO2-SvO2)×0.2. Variance components and mean standard deviations were analyzed after introduction of the quality criteria. Variance components of reapplication and measurement decreased after introduction of the second quality criterion (TOI: 46.6-35.0%, SvO2: 76.8-38.2%, FOE: 73.1-37.5%, Hbflow: 70.3-51.9%, DO2: 71.5-52.7%, and VO2: 70.9-63.8%). Mean standard deviations of TOI (6.6±3.0 to 4.7±3.2%), SvO2 (11.1±4.8 to 5.7±3.9%), FOE (11.3±4.8 to 5.9±4.0%), Hbflow (4.3±2.0 to 2.9±1.6μmol/100mL/min), and DO2 (17.8±7.6 to 11.4±6.2μmol/100mL/min) decreased significantly, too. Only 12% of measurements fulfilled both quality criteria. With the introduction of two quality criteria, test-retest variability of peripheral NIRS measurements decreased significantly and reproducibility increased significantly. © 2009 Society of Photo-Optical Instrumentation Engineers.

Cite

CITATION STYLE

APA

Pichler, G., Grossauer, K., Peichl, E., Gaster, A., Berghold, A., Schwantzer, G., … Urlesberger, B. (2009). Combination of different noninvasive measuring techniques: a new approach to increase accuracy of peripheral near infrared spectroscopy. Journal of Biomedical Optics, 14(1), 014014. https://doi.org/10.1117/1.3076193

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley