Intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians

26Citations
Citations of this article
56Readers
Mendeley users who have this article in their library.

Abstract

Background: Muscle wasting is common among critically ill patients with sepsis and has a significant effect on clinical outcome. However, appropriate tool for measurement of muscle loss is debatable. Ultrasonography (USG) has been used for objective assessment of quadriceps muscle thickness among these patients; however, there is limited data on its reliability. Aims and Objective: This study was aimed to assess the reliability of quadriceps muscle thickness as measured by critical care physicians. Methodology: This cross-sectional study included twenty patients with sepsis. Quadriceps muscle thickness was measured on right mid-thigh at a predefined point by two critical care fellows using bedside USG. Intra- and inter-observer reliability of the measurements was assessed by intra-class correlation coefficient (ICC). Results: Hundred and twenty quadriceps muscle thickness measurements, three by each of the two critical care fellows, were done in twenty patients with sepsis. First, second, and third measurements (mean ± standard deviation) taken by the first observer (RK) were 35.030 ± 3.546 mm, 35.055 ± 3.307 mm, and 35.245 ± 3.027 mm, respectively. The three values recorded by the second observer (AD) were 35.585 ± 3.746 mm, 35.1 ± 3.006 mm, and 34.89 ± 2.556 mm, respectively. ICC for observer 1 and 2 was 0.925 (95% confidence interval [CI]: 0.851-0.967) and 0.835 (95% CI: 0.689-0.925), respectively. The mean difference of measurement between two observers was 0.082 mm (95% CI: -1.194-1.031). The mean ICC (95% CI) for inter-observer reliability was 0.992 (0.979-0.997); P < 0.001. Conclusions: This study shows that ultrasound is a reliable tool for the measurement of quadriceps muscle thickness by critical care physicians with excellent inter- and intra-class reliability.

Cite

CITATION STYLE

APA

Hadda, V., Khilnani, G. C., Kumar, R., Dhunguna, A., Mittal, S., Khan, M. A., … Guleria, R. (2017). Intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians. Indian Journal of Critical Care Medicine, 21(7), 448–452. https://doi.org/10.4103/ijccm.IJCCM_426_16

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free