Abstract
Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners.
Cite
CITATION STYLE
Lee, J., Lim, C. H., Park, J.-W., Kim, I.-H., Moon, M. K., & Lim, Y.-K. (2017). The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signalto-noise Ratio Improvement Factor in Container Scanner X-ray Imaging. Journal of Radiation Protection and Research, 42(4), 197–204. https://doi.org/10.14407/jrpr.2017.42.4.197