Variation of densitometry on computed tomography in COPD-Influence of different software tools

30Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

Abstract

Objectives: Quantitative multidetector computed tomography (MDCT) as a potential biomarker is increasingly used for severity assessment of emphysema in chronic obstructive pulmonary disease (COPD). Aim of this study was to evaluate the user-independent measurement variability between five different fully-automatic densitometry software tools. Copyright: Material and Methods: MDCT and full-body plethysmography incl. forced expiratory volume in 1s and total lung capacity were available for 49 patients with advanced COPD (age = 6469 years, forced expiratory volume in 1s = 31 66% predicted). Measurement variation regarding lung volume, emphysema volume, emphysema index, and mean lung density was evaluated for two scientific and three commercially available lung densitometry software tools designed to analyze MDCT from different scanner types. Results:One scientific tool and one commercial tool failed to process most or all datasets, respectively, and were excluded. One scientific and another commercial tool analyzed 49, the remaining commercial tool 30 datasets. Lung volume, emphysema volume, emphysema index and mean lung density were significantly different amongst these three tools (p<0.001). Limits of agreement for lung volume were [-0.195,-0.052l], [-0.305,-0.131l], and [-0.123,-0.052l] with correlation coefficients of r= 1.00 each. Limits of agreement for emphysema index were [26.2, 2.9%], [227.0, 16.9%], and [2 25.5, 18.8%], with r = 0.79 to 0.98. Correlation of lung volume with total lung capacity was good to excellent (r = 0.77 to 0.91, p<0.001), but segmented lung volume (6.7±1.3-6.8±1.3l) were significantly lower than total lung capacity (7.7±1.7l, p<0.001). Conclusions: Technical incompatibilities hindered evaluation of two of five tools. The remaining three showed significant measurement variation for emphysema, hampering quantitative MDCT as a biomarker in COPD. Follow-up studies should currently use identical software, and standardization efforts should encompass software as well.

Cite

CITATION STYLE

APA

Wielpütz, M. O., Bardarova, D., Weinheimer, O., Kauczor, H. U., Eichinger, M., Jobst, B. J., … Heussel, C. P. (2014). Variation of densitometry on computed tomography in COPD-Influence of different software tools. PLoS ONE, 9(11). https://doi.org/10.1371/journal.pone.0112898

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free