A fast MR-thermometry method for quantitative assessment of temperature increase near an implanted wire

5Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose To propose a MR-thermometry method and associated data processing technique to predict the maximal RF-induced temperature increase near an implanted wire for any other MRI sequence. Methods A dynamic single shot echo planar imaging sequence was implemented that interleaves acquisition of several slices every second and an energy deposition module with adjustable parameters. Temperature images were processed in real time and compared to invasive fiber-optic measurements to assess accuracy of the method. The standard deviation of temperature was measured in gel and in vivo in the human brain of a volunteer. Temperature increases were measured for different RF exposure levels in a phantom containing an inserted wire and then a MR-conditional pacemaker lead. These calibration data set were fitted to a semi-empirical model allowing estimation of temperature increase of other acquisition sequences. Results The precision of the measurement obtained after filtering with a 1.6x1.6 mm2 in plane resolution was 0.2oC in gel, as well as in the human brain. A high correspondence was observed with invasive temperature measurements during RF-induced heating (0.5oC RMSE for a 11.5oC temperature increase). Temperature rises of 32.4oC and 6.5oC were reached at the tip of a wire and of a pacemaker lead, respectively. After successful fitting of temperature curves of the calibration data set, temperature rise predicted by the model was in good agreement (around 5% difference) with measured temperature by a fiber optic probe, for three other MRI sequences. Conclusion This method proposes a rapid and reliable quantification of the temperature rise near an implanted wire. Calibration data set and resulting fitting coefficients can be used to estimate temperature increase for any MRI sequence as function of its power and duration.

Cite

CITATION STYLE

APA

Delcey, M., Bour, P., Ozenne, V., Hassen, W. B., & Quesson, B. (2021). A fast MR-thermometry method for quantitative assessment of temperature increase near an implanted wire. PLoS ONE, 16(5 May). https://doi.org/10.1371/journal.pone.0250636

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free