INTRODUCTION Extensive regulations have been introduced to reduce secondhand smoke (SHS) exposure among non-smokers in Malaysia. However, there is still a need to encourage behavior change of smokers in relation to making homes smoke-free. This feasibility study aimed to use low-cost air pollution monitors to quantify SHS concentrations in Malaysian households and to explore the practicality of using personalized feedback in educating families to make their homes smoke-free. METHODS A total of 35 smokers in three states in Malaysia were recruited via snowball and convenience sampling methods. Indoor fine particulate (PM2.5) concentrations in participants' homes were measured for 7 days before and after educational intervention using a pre-defined template, which included personalized air-quality feedback, and information on SHS impacts were given. The feedback was delivered over two 20-minute phone calls or in-person sessions following the completion of the air-quality measurements. Data were corrected for outdoor PM2.5 concentrations from the nearest environmental monitor. RESULTS Despite the challenges in conducting the project during COVID-19 pandemic, the delivery of the intervention was found to be feasible. Twenty-seven (77%) out of 35 participants completed PM2.5 measurements and received a complete intervention. The median (IQR: 25th -75th percentile concentrations) SHS-PM2.5 concentrations at baseline and follow-up were 18.3 µg/m3 (IQR: 13.3-28.3) and 16.2 µg/m3 (IQR: 10.4 - 25.6), respectively. There was a reduction of SHS-PM2.5 concentrations at follow-up measurement in the houses of 17 participants (63%). The change in corrected indoor PM2.5 concentrations between baseline and followup was not statistically significant (Z= -1.01, p=0.29). CONCLUSIONS This educational intervention, combining the use of a low-cost air particle counter with personalized air-quality feedback, was found to be feasible in the Malaysian setting. It has potential to trigger behavior change among smokers, reducing indoor smoking and consequent SHS concentrations, and increasing smoke-free home implementation. A large-scale trial is needed.
Author supplied keywords
Cite
CITATION STYLE
Zulkifli, A., Abd Rani, N. L., Mutalib, R. N. S. A., Dobson, R., Ibrahim, T. A. E., Abd Latif, N. H., … Semple, S. (2022). Measuring secondhand smoke in homes in Malaysia: A feasibility study comparing indoor fine particulate (PM2.5) concentrations following an educational feedback intervention to create smoke-free homes during the COVID-19 pandemic. Tobacco Induced Diseases, 20(July). https://doi.org/10.18332/tid/150338
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.