Abstract
A cooling tower scheme that quantifies the sensible and latent anthropogenic heat fluxes released from buildings was coupled to an operational forecasting system [Rapid Refresh Multiscale Analysis and Prediction of the Beijing Urban Meteorological Institute (RMAPS-Urban)] and was evaluated in the context of the megacity of Beijing, China, during summer months. The objective of this scheme is to correct for un-derestimations of surface latent heat fluxes in regional climate modeling and weather forecasts in urban areas. The performance for surface heat fluxes by the modified RMAPS-Urban is greatly improved when compared with a suite of observations in Beijing. The cooling tower scheme increases the anthropogenic latent heat partition by 90% of the total anthropogenic heat flux release. Averaged surface latent heat flux in urban areas increases to about 64.3 W m22 with a peak of 150 W m22 on dry summer days and 40.35 W m22 with a peak of 150 W m22 on wet summer days. The model performance of near-surface temperature and humidity is also improved. Average 2-m temperature errors are reduced by 18C, and maximum and minimum temperature errors are improved by 28–38C; absolute humidity is increased by 5%.
Cite
CITATION STYLE
Yu, M., González, J., Miao, S., & Ramamurthy, P. (2019). On the assessment of a cooling tower scheme for high-resolution numerical weather modeling for urban areas. Journal of Applied Meteorology and Climatology, 58(6), 1399–1415. https://doi.org/10.1175/JAMC-D-18-0126.1