Clinical evaluation of left ventricular function and morphology using an accelerated k-t sensitivity encoding method in cardiovascular magnetic resonance

2Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: To provide clinical validation of a recent 2D SENSE-based accelerated cardiovascular magnetic resonance (CMR) sequence (accelerated k-t SENSE), investigating whether this technique accurately quantifies left ventricle (LV) volumes, function, and mass as compared to 2D cine steady-state free precession (2D-SSFP). Methods: Healthy volunteers (n = 16) and consecutive heart failure patients (n = 26) were scanned using a 1.5 T MRI system. Two LV short axis (SA) stacks were acquired: (1) accelerated k-t SENSE (5–6 breath-holds; temporal/spatial resolution: 37 ms/1.82 × 1.87 mm; acceleration factor = 4) and (2) standard 2D-SSFP (10–12 breath-holds; temporal/spatial resolution: 49 ms/1.67 × 1.87 mm, parallel imaging). Ascending aorta phase-contrast was performed on all volunteers as a reference to compare LV stroke volumes (LVSV) and validate the sequences. An image quality score for SA images was used, with lower scores indicating better quality (from 0 to 18). Results: There was a high agreement between accelerated k-t SENSE and 2D-SSFP for LV measurements: bias (limits of agreement) of 2.4% (− 5.4% to 10.1%), 6.9 mL/m2 (− 4.7 to 18.6 mL/m2), − 1.5 (− 8.3 to 5.2 mL/m2), and − 0.2 g/m2 (− 11.9 to 12.3 g/m2) for LV ejection fraction, end-diastolic volume index, end-systolic volume index, and mass index, respectively. LVSV by accelerated k-t SENSE presented good agreement with aortic flow. Interobserver and intraobserver variabilities for all LV parameters were also high. Conclusion: The accelerated k-t SENSE CMR sequence is clinically feasible and accurately quantifies LV volumes, function, and mass, with short acquisition time and good image quality.

Cite

CITATION STYLE

APA

Assuncao-Jr, A. N., Dantas-Jr, R. N., do Val, R. M., Gianotto, P., Marin, A. dos S., Golden, M., … Nomura, C. H. (2019). Clinical evaluation of left ventricular function and morphology using an accelerated k-t sensitivity encoding method in cardiovascular magnetic resonance. Insights into Imaging, 10(1). https://doi.org/10.1186/s13244-019-0750-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free