Abstract
The performance of a nuclear radiation detector fabricated from Vertical Gradient Freeze (VGF) semi-insulating Fe-doped InP was investigated. Pulse height spectra were acquired when the detector was irradiated with alpha particles from 241Am, as a function of temperature and detector bias voltage. The spectroscopic performance of the detector was limited at room temperature due to the presence of a high leakage current. At a bias of -150 V, a room temperature leakage current density of 2.4 × 10-6 A/mm2 was observed which reduced to 7.1 × 10-8 A/mm2 at a temperature of -21°C. By biasing the irradiated detector contact at either a negative or positive potential, the charge collection efficiency (CCE) was measured separately for pulses produced predominantly by electron transport and for pulses produced predominantly by hole transport, respectively. At -21°C a maximum CCE of 72% was obtained for the electron signal and 44% for the hole signal. As a function of bias the CCE of the electrons remained constant in the temperature range -21°C to +19°C, whilst that of the holes exhibited a significant variation. By comparison with the Hecht relationship estimates of the carrier mobility-lifetime (μτ) products are deduced, which are similar for both holes and electrons and in the range 5 × 10-7-8 × 10-7 cm2/V. A reduction in μτ is observed at lower temperature for holes, whereas the value for electrons remains constant over the temperature range studied. © 2001 Elsevier Science B.V.
Author supplied keywords
Cite
CITATION STYLE
El-Abbassi, H., Rath, S., & Sellin, P. J. (2001). Characterisation of vertical gradient freeze semi-insulating InP for use as a nuclear radiation detector. In Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment (Vol. 466, pp. 47–51). https://doi.org/10.1016/S0168-9002(01)00823-3
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.