Measurement report: Evaluation of the TOF-ACSM-CV for PM1.0 and PM2.5 measurements during the RITA-2021 field campaign

3Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

The recently developed time-of-flight aerosol chemical speciation monitor with a capture vaporizer and a PM2.5 aerodynamic lens (TOF-ACSM-CV-PM2.5) aims to improve the collection efficiency and chemical characterization of aerosol particles with a diameter smaller than 2.5 μm. In this study, comprehensive cross-comparisons were performed between real-time online measurements and offline filter analysis with 24 h collection time. The goal was to evaluate the capabilities of the TOF-ACSM-CV-PM2.5 lens, as well as the accuracy of the TOF-ACSM-CV-PM2.5. The experiments were conducted at Cabauw Experimental Site for Atmospheric Research (CESAR) during the RITA-2021 campaign. The non-refractory fine particulate matter (PM1.0 and PM2.5) was measured by two collocated TOF-ACSM-CV-PM2.5 instruments by placing them behind a PM2.5 and PM1.0 inlet, respectively. A comparison between the ACSMs and PM2.5 and PM1.0 filter samples showed a much better accuracy than ±30 % less given in the previous reports, with average differences less than ±10 % for all inorganic chemical species. In addition, the ACSMs were compared to the Monitoring Instrument for Aerosol and Gas (MARGA) (slope between 0.78 and 0.97 for inorganic compounds, R2≥ 0.93) and a mobility particle size spectrometer (MPSS), measuring the particle size distribution from around 10 to 800 nm (slope was around 1.00, R2 = 0.91). The intercomparison of the online measurements and the comparison between the online and offline measurements indicated a low bias (< 10 % for inorganic compounds) and demonstrated the high accuracy and stability of the TOF-ACSM-CV-PM2.5 lens for the atmospheric observations of particle matter. The two ACSMs exhibited an excellent agreement, with differences less than 7 %, which allowed a quantitative estimate of PM1.0 vs. PM2.5 chemical composition. The result showed that the PM1.0 accounted for about 70 %-80 % of the PM2.5 on average. The NO3 mass fraction increased, but the organic carbon (OC) mass fraction decreased from PM1.0 to PM2.5, indicating the size dependence on chemical composition.

Cite

CITATION STYLE

APA

Liu, X., Henzing, B., Hensen, A., Mulder, J., Yao, P., Van Dinther, D., … Dusek, U. (2024). Measurement report: Evaluation of the TOF-ACSM-CV for PM1.0 and PM2.5 measurements during the RITA-2021 field campaign. Atmospheric Chemistry and Physics, 24(6), 3405–3420. https://doi.org/10.5194/acp-24-3405-2024

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free