Monitoring cardiac function in intensive care

125Citations
Citations of this article
168Readers
Mendeley users who have this article in their library.

Abstract

Systolic cardiac function results from the interaction of four interdependent factors: heart rate, preload, contractility, and afterload. Heart rate can be quantified easily at the bedside, while preload estimation has traditionally relied on invasive pressure measurements, both central venous and pulmonary artery wedge. These have significant clinical limitations; however, adult literature has highlighted the superiority of several novel preload measures. Measurement of contractility and afterload is difficult; thus in clinical practice the bedside assessment of cardiac function is represented by cardiac output. A variety of techniques are now available for cardiac output measurement in the paediatric patient. This review summarises cardiac function and cardiac output measurement in terms of methodology, interpretation, and their contribution to the concepts of oxygen delivery and consumption in the critically ill child.

Cite

CITATION STYLE

APA

Tibby, S. M., & Murdoch, I. A. (2003, January 1). Monitoring cardiac function in intensive care. Archives of Disease in Childhood. https://doi.org/10.1136/adc.88.1.46