Effect of Different Splint Thicknesses on Occlusal Function and Temporomandibular Joint Sounds: A Clinical Report

  • Tang Y
  • Li H
  • Chen Y
  • et al.
N/ACitations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Background: Occlusal splint therapy, which is a conservative approach to treat temporomandibular disorders (TMDs) and bruxism, can change the occlusal contact of dentition. However, little is known about the variation in bite force and temporomandibular joint (TMJ) sounds. The objective of this case report is to compare the effects of different splint thicknesses constructed by vacuum lamination technology on occlusal function and TMJ sounds. Clinical Presentation: This study presents a 24-year-old male with bruxism. Four splints of different thicknesses (0.6 mm, 1 mm, 2.5 mm and 3 mm) were fabricated and tested. Then, an array of occlusal data were recorded and analyzed by the T-Scan®III system and joint vibration analysis (JVA). Conclusion: The results reveal that splints of different thicknesses manufactured by the vacuum hot-lamination apparatus may cause a change in occlusal force.