Measurement of mass attenuation coefficients of the fabricated Rhizophora spp. particleboards at high energy photons by using Compton scattering method

3Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The mass attenuation coefficients of the fabricated Rhizophora spp. particleboards were measured by using the Compton scattering technique and Ludlum configurations. The mass attenuation coefficents of the particleboards were measured at scattered gamma energies of 137Cs between 337.72 and 564.09 keV and compared to the its theoretical values and the values of water by using XCOM calculation. The results showed that the measured mass attenuation coefficients of the fabricated Rhizophora spp. particleboards were in good agreement to its theoretical values and water (XCOM) within 3.8 and 5.9% discrepancies. The results showed the near attenuation properties of the fabricated Rhizophora spp. particleboards to water at scattered gamma energies and the suitability of the Ludlum configuration for the measurement of mass attenuation coefficients of materials.

Cite

CITATION STYLE

APA

Mohd Yusof, M. F., Abd Hamid, P. N. K., Mohd Isa, N., Abd Kadir, A. B., & Salleh, H. (2019). Measurement of mass attenuation coefficients of the fabricated Rhizophora spp. particleboards at high energy photons by using Compton scattering method. In IOP Conference Series: Materials Science and Engineering (Vol. 555). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/555/1/012029

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free