Abstract
In this study, a medium voltage electrical stimulation (ES) system with three parameter combinations (A: 1A, 1.55 ms pulse width, 27 s; B: 0.55A, 1 ms pulse width, 34 s; C: 0.55A, 2 ms pulse width, 20s) were applied to beef carcases (n = 24; 319 ± 26.4 kg), in the context of a very slow pH decline rate in the abattoir. All the ES combinations significantly accelerated the rate of pH decline (reflected by temp@pH 6.0, i.e. temperature when pH drops to 6.0), resulting in a tenderness improvement even after 14 days ageing compared to the controls. Sarcomere length was not different between treatments and controls, and it was not a contributor to the tenderness improvement, instead, physical disruption revealed by transmission electron microscopic images may have led to the improvement. Retail colour was significantly improved by either combination B or C after 7 days of ageing. Combination B shows the most promise for commercial application, however, verification on more animals is required before commercial adoption.
Author supplied keywords
Cite
CITATION STYLE
Zhang, Y., Ji, X., Mao, Y., Luo, X., Zhu, L., & Hopkins, D. L. (2019). Effect of new generation medium voltage electrical stimulation on the meat quality of beef slaughtered in a Chinese abattoir. Meat Science, 149, 47–54. https://doi.org/10.1016/j.meatsci.2018.11.011
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.