Underfilled balloon-expandable transcatheter aortic valve implantation with ad hoc post-dilation: Pulsatile flow simulation using a patient-specific three-dimensional printing model

4Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

Abstract

Background: Underfilled transcatheter aortic-valve implantation with ad hoc post-dilation is a therapeutic option for patients with borderline annuli to avoid acute complication. The effects of this technique on valve leaflet behavior, hydrodynamic performances, and paravalvular leakage (PVL) using patient-specific three-dimensional (3D) aortic-valve models were investigated. Methods and Results: A female octogenarian patient was treated with this technique by using a 23-mm Sapien-XT. Patient-specific models were constructed from pre-procedure computed tomography (CT) data. Change in aortic annulus areas during systolic/ diastolic phases and post-procedure stent areas were adjusted to those of the patient. The following was performed: (1) -3 cc initial and -2 cc underfilled post-dilation to the scale-down model by adjusting percent oversizing; and (2) -1 cc initial underfilling, nominal volume, and repeat nominal volume post-dilation using the patient-specific model. Underfilling was associated with higher %PVL. Observation using a high-speed camera revealed distorted leaflets after underfilled implantation, with a longer valve-closing time and smaller effective orifice areas, especially in the -3 cc underfilled implantation. Micro-CT analysis revealed that the transcatheter valves shifted to the opposite side of the large annulus calcification after post-dilation and reduced the malapposition there. Conclusions: Excessive underfilled implantation showed unacceptable acute hemodynamics. Abnormal leaflet motions after underfilled implantation raised concerns about durability. Flow simulations using patient-oriented 3D models could help to investigate hemodynamics, leaflet motions, and the PVL mechanism.

Cite

CITATION STYLE

APA

Yamawaki, M., Obama, K., Sasuga, S., Takahashi, A., Ito, Y., Umezu, M., & Iwasaki, K. (2019). Underfilled balloon-expandable transcatheter aortic valve implantation with ad hoc post-dilation: Pulsatile flow simulation using a patient-specific three-dimensional printing model. Circulation Journal, 83(2), 461–470. https://doi.org/10.1253/circj.CJ-18-0582

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free