High-Sensitivity Accelerometry with a Feedback-Cooled Magnetically Levitated Microsphere

45Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We show that a magnetically levitated microsphere in high vacuum can be used as an accelerometer by comparing its response to that of a commercially available geophone. This system shows great promise for ultrahigh acceleration sensitivities without the need for large masses or cryogenics. With feedback cooling, the transient decay time is reduced and the center-of-mass motion is cooled to 9 K or less. Remarkably, the levitated-particle accelerometer has a sensitivity down to 3.6×10-8g/Hz and gives measurements similar to those of the commercial geophone at frequencies up to 14 Hz despite a test mass that is four billion times smaller. With no free parameters in the calibration, the responses of the accelerometers match within 3% at 5 Hz. The system reaches this sensitivity due to a relatively large particle mass of 0.25μg, a low center-of-mass oscillation frequency of 1.75 Hz, and an image-analysis method that can measure the displacement with an uncertainty of 1.6 nm in a single image.

Cite

CITATION STYLE

APA

Lewandowski, C. W., Knowles, T. D., Etienne, Z. B., & D’Urso, B. (2021). High-Sensitivity Accelerometry with a Feedback-Cooled Magnetically Levitated Microsphere. Physical Review Applied, 15(1). https://doi.org/10.1103/PhysRevApplied.15.014050