Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in predrug-eluting stent era

181Citations
Citations of this article
115Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We conducted a formal meta-analysis of peer-reviewed, published, randomized studies comparing intravascular ultrasound (IVUS)-guidance and angiographic-guided bare metal stent implantation. A total of 8 studies were identified. Because the Balloon Equivalent to Stent (BEST) study was a noninferiority trial designed to compare 2 very different percutaneous coronary intervention strategiesIVUS-guided aggressive balloon angioplasty (with bail-out stenting) and angiographic-guided deliberate bare metal stent implantationit was eliminated. An unadjusted random-effects meta-analysis was used to compare the IVUS-guided and nonIVUS-guided stenting in the 7 remaining studies. A total of 2,193 patients were randomized in 5 multicenter and 2 single-center studies. IVUS guidance was associated with a significantly larger postprocedure angiographic minimum lumen diameter. The mean difference was 0.12 mm (95% confidence interval [CI] 0.06 to 0.18, p <0.0001). IVUS guidance was also associated with a significantly lower rate of 6-month angiographic restenosis (22% vs 29%, odds ratio 0.64, 95% CI 0.42 to 0.96, p = 0.02), a significant reduction in the revascularization rate (13% vs 18%, odds ratio 0.66, 95% CI 0.48 to 0.91, p = 0.004), and overall major adverse cardiac events (19% vs. 23%, odds ratio 0.69, 95% CI 0.49 to 0.97, p = 0.03). However, no significant effect was seen for myocardial infarction (p = 0.51) or mortality (p = 0.18). In conclusion, IVUS guidance for bare metal stent implantation improved the acute procedural results (angiographic minimum lumen diameter) and thereby reduced angiographic restenosis and repeat revascularization and major adverse cardiac events, with a neutral effect on death and myocardial infarction during a follow-up period of 6 months to 2.5 years. © 2011 Elsevier Inc. All rights reserved.

Cite

CITATION STYLE

APA

Parise, H., Maehara, A., Stone, G. W., Leon, M. B., & Mintz, G. S. (2011). Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in predrug-eluting stent era. American Journal of Cardiology, 107(3), 374–382. https://doi.org/10.1016/j.amjcard.2010.09.030

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free