Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions

23Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: Histological verification of pulmonary lesions is important to ensure correct treatment. Computed tomographic (CT) transthoracic core biopsy is a well-established procedure for this. Comparison of available studies is difficult though, as technical and patient characteristics vary. Using a standardized biopsy technique, we evaluated our results for CT-guided coaxial core biopsy in a semi-automatic technique. Materials and Methods: Within 2 years, 664 consecutive transpulmonary biopsies were analyzed retrospectively. All interventions were performed using a 17/18G semi-automatic core biopsy system (4 to 8 specimens). The incidence of complications and technical and patient-dependent risk factors were evaluated. Results: Comparing the histology with the final diagnosis, the sensitivity was 96.3 %, and the specificity was 100 %. 24 procedures were not diagnostic. In all others immunohistological staining was possible. The main complication was pneumothorax (PT, 21.7 %), with chest tube insertion in 6 % of the procedures (n = 40). Bleeding without therapeutic consequences was seen in 43 patients. There was no patient mortality. The rate of PT with chest tube insertion was 9.6 % in emphysema patients and 2.8 % without emphysema (p = 0.001). Smokers with emphysema had a 5 times higher risk of developing PT (p = 0.001). Correlation of tumor size or biopsy angle and the risk of PT was not significant. The risk of developing a PT was associated with an increasing intrapulmonary depth of the lesion (p = 0.001). Conclusion: CT-guided, semiautomatic coaxial core biopsy of the lung is a safe diagnostic procedure. The rate of major complications is low, and the sensitivity and specificity of the procedure are high. Smokers with emphysema are at a significantly higher risk of developing pneumothorax and should be monitored accordingly. Key points: •Using an 18G core biopsy system with 6 specimens will allow immunohistological staining with high sensitivity and specificity. •Smokers with emphysema are at a significantly higher risk of developing a pneumothorax. Citation Format: •Schulze R, Seebacher G, Enderes B. et al. Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions. Fortschr Röntgenstr 2015; 187: 697 - 702.

Cite

CITATION STYLE

APA

Schulze, R., Seebacher, G., Enderes, B., Kugler, G., Fischer, J. R., & Graeter, T. P. (2015). Complications in CT-Guided, Semi-Automatic Coaxial Core Biopsy of Potentially Malignant Pulmonary Lesions. RoFo Fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren, 187(8), 697–702. https://doi.org/10.1055/s-0034-1399648

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free