Implant-Prosthodontic Discrepancy of Complete-Arch Cobalt-Chromium Implant Frameworks Manufactured Through Selective Laser Melting Additive Manufacturing Technology Using a Coordinate Measuring Machine

  • Revilla-León M
  • Ceballos L
  • Özcan M
19Citations
Citations of this article
52Readers
Mendeley users who have this article in their library.
Get full text

Abstract

© 2019 by Quintessence Publishing Co Inc. Purpose: The objective was to measure the implant-prosthodontic discrepancy of complete-arch implant-supported frameworks made of cobalt-chromium (Co-Cr) fabricated using selective laser melting (SLM) additive manufacturing technologies. Materials and Methods: A completely edentulous maxillary cast with seven implant replicas was obtained. Co-Cr SLM frameworks (n = 9) from three different providers (SLM-1, SLM-2, SLM-3) were manufactured. A coordinate measuring machine was selected to measure the implant-prosthodontic discrepancy (μm) on the x-, y-, and z-axes and the 3D gap (3D = x2 + y2 + z2 where implantswereconsideredasthestatisticalunit(n=7).One-wayanalysisofvariance(ANOVA),Student-Newman-Keuls, and Tukey tests were used to analyze the data (α = .05). Results: The mean 3D implant-prosthodontic discrepancy (μm) was higher for SLM-1 (73.77 ± 27.94) than for SLM-2 (47.54 ± 22.63) and SLM-3 (47.26 ± 22.57). At the x-axis, SLM-2 showed a significantly smaller gap (16.21 ± 9.6) than SLM-3 (32.92 ± 27.77) and SLM-1 (34.77 ± 21.85). At the y-axis, however, SLM-3 presented a significantly smaller gap (27.97 ± 9.49) than SLM-2 (38.84 ± 27.82) and SLM-1 (54.35 ± 29.89). Similarly, at the z-axis, SLM-3 (4.01 ± 2.29) showed the least gap, followed by SLM-2 (9.09 ± 7.63), which was significantly smaller than that of SLM-1 (16.14 ± 21.09). Conclusion: The three SLM additive manufacturing technologies tested showed implant-prosthodontic discrepancies ranging from 4.01 to 54.35 μm, which could be considered in the clinically acceptable range. Distortion at the z-axis was significantly less compared with the x- and y-axes in all the groups tested. INT J ORAL MAXILLOFAC IMPLANTS 2019;34:698–707. doi: 10.11607/jomi.6739

Cite

CITATION STYLE

APA

Revilla-León, M., Ceballos, L., & Özcan, M. (2019). Implant-Prosthodontic Discrepancy of Complete-Arch Cobalt-Chromium Implant Frameworks Manufactured Through Selective Laser Melting Additive Manufacturing Technology Using a Coordinate Measuring Machine. The International Journal of Oral & Maxillofacial Implants, 34(3), 698–707. https://doi.org/10.11607/jomi.6739

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free